Product Details:
Minimum Order Quantity | 1 Piece |
Model Number | 3690AUTO |
AC Current | 400A,600A |
Usage/Application | To Check Current |
DC Voltage | 400mV,4V,40V,400V,600V |
Brand | Meco |
Warranty | 1 Year |
Jaw Open | 30 mm |
Digit Display | 3-4 |
AC Voltage | 4V,40V,400V,600V |
Frequency | 100Hz,1KHz,10KHz,100KHz,500KHz |
Technical Specifications
Models
3690Auto
AC Current
400A, 600A
AC Voltage
4V, 40V, 400V, 600V
DC Current
400A, 600A
DC Voltage
400mV, 4V, 40V, 400V, 600V
Resistance
400Ω, 4KΩ, 40KΩ, 400KΩ, 4MΩ, 40MΩ
Frequency
100Hz, 1KHz, 10KHz,100KHz, 500KHz
Sp. Functions
Data Hold, Audible Continuity, Diode Test, APO
Jaw Opening
Cable Dia. 30mm max.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Digit Display | 4 Digit |
DC Voltage | 200m-2V 0.5,20-200-600V 0.8 |
AC Voltage | 200-600V 1.5 |
Battery | 6F22 9V X 1 |
Size | 138 X 69 X 31mm |
Display Type | Digital |
Item weight | 170g |
Power | 6F22 9V X 1 |
We are betrothed to provide a high quality collection of Digital Multimeter. The offered digital multimeter is used in various electrical and electronic applications for reading of voltage and current level. This digital multimeter is manufactured at our hi-tech production unit using the best quality components and advanced technology under the strict guidance of our highly skilled professionals. Moreover, this digital multimeter can be availed by our clients at the most reasonable rates.
Techincal Specification :
Display: 1999
Voltage DC: 200m/2V ± 0.5%,20/200/600V ± 0.8%
Voltage AC: 200/600V ± 1.5%
Current DCt: 200μ/2m/20mA ± 1.0%, 200mA± 2.0%, 10A ± 3.0%
Resistance: 200/2K/20K/200K/2MΩ ± 1.0%
hFE: 1 ~ 1000
Diode test Data hold
Back light
Continuity checking with Buzzer
Power: 6F22(9V) × 1Dimension: 138 × 69 × 31mm
Weight:170g (batteries included)
Additional Information:
Product Details:
Minimum Order Quantity | 1 Number |
Model Name/Number | DCM801F |
Brand | Meco |
DC Voltage Range | 2V/20V/200V - 1000V |
AC Voltage Range | 200V-750V |
Frequency Range | 2kHz |
Display | 2000 Counts |
Power supply | 9V 6F22 Battery |
Specifications
Range
Accuracy
M266F
DC Voltage
2V/20V/200V
1000V
+-(0.5% 3)
+-(0.8% 3)
AC Voltage
200V
750V
+-(1.0% 5)
+-(1.2% 5)
AC Current
200A
1000A
+-(2.5% 5)
+-(3.0% 10)
Resistance
200/2k/20k/200k/2M
+-(1.0% 8)
Insulation
20M
2000M
+-(2.0% 2)
+-(5.0% 2)
Frequency
2kHz
+-(2.0% 5)
Feature
Display
2000 Counts
Data hold
Diode
Continuity
Insulation test
General
Power supply
9V 6F22 Battery
Weight
Approx 260g
Size
235mmx96mmx46mm
Jaw Size
50mm
Safety Rating
CE CAT.II1000V CAT.III600V RoHS
Product Details:
Minimum Order Quantity | 1 Piece |
Model Number | Fluke 106 |
Brand | Fluke |
Warranty | 1 Year |
Digit Display | 4 Digit |
DC Voltage | 0-600 V V |
Features | Safety rating by CAT III 600 VAC/DC current, AC/DC voltage |
DC Current | 0-10 A |
AC Voltage | 600mV to 600 V |
Accuracy | 1.0 |
DC Voltage Accuracy | 0.5 |
Resistance Range | 0-40 M |
DC Current Accuracy | 1.5 |
Item weight | 200 g |
Frequency | 50Hz - 100 kHz |
Category | Electrical Power Testing |
Dimensions | 142x69x28 mm |
ccuracy Specifications | ||||
Function | Range | Resolution | Accuracy | |
AC Volts1 | 6.000 V 60.00 V 600.0 V | 0.001 V 0.01 V 0.1 V | 1.0 % + 3 | |
DC Volts | 6.000 V 60.00 V 600.0 V | 0.001 V 0.01 V 0.1 V | 0.5 % + 3 | |
AC Millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 | |
Diode Test2 | 2.000 V | 0.001 V | 10 % | |
Resistance (Ohms) | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ | 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 | |
Capacitance3 | 50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000 μF | 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF | 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 | |
Frequency4 Hz (10 Hz – 100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | NA | |
Duty Cycle4 | 1 % to 99 % | 0.1 % | NA | |
AC Current (40 Hz to 200 Hz) | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | |
DC Current | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
colour | Yellow |
V AC Range | 600.0mV |
V AC Accuracy | 3.0 3digit |
Resistance Ohms Ra | 400.0 |
BRAND | FLUKE |
V AC Resolution | 0.1mV |
V DC Range | 6.000V |
V DC Resolution | 0.001V |
V DC Accuracy | 0.5 3 digit |
|
V AC (40-500Hz) | Range | 600.0 mV 6.000 V 60.00 V 600.0 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V | |
Accuracy | 3.0%±3 digit 1.0%±3 digit | |
V DC | Range | 6.000 V 60.00 V 600.0 V |
Resolution | 0.001 V 0.01 V 0.1 V | |
Accuracy | 0.5%±3 digit | |
Resistance Ohms | Range | 400.0 4.000 k 40.00 k 400.0 k 4.000 M 40.00 M |
Resolution | 0.1 0.001 k 0.01 k 0.1 k 0.001 M 0.01 M | |
Accuracy | 0.5 %±3 digit 0.5 %±2 digit 0.5 %±2 digit 0.5 %±2 digit 0.5 %±2 digit 1.5%±3 digit | |
Capacitance | Range | 50.00 nF 500.0 nF 5.000 μF 50.00 μF 100.0 μF |
Resolution | 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF | |
Frequency (10 Hz – 100 kHz) | Range | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | |
Duty Cycle | Range | 0.1 % to 99.9 % |
Resolution | 0.1 % | |
Additional Information:
Product Details:
Model Number | 15B FLUKE |
Brand | Fluke |
Digit Display | 4 Digit |
DC Voltage | 4.000 V |
AC Current | 400.0 A |
DC Current | 400.0 A |
AC Voltage | 4.000 V |
DC Voltage Accuracy | 0.5 |
Display Type | Digtal |
Function | Range | Resolution | Accuracy | |
AC volts (40 Hz to 500Hz)1 | 4.000 V 40.00 V 400.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 1.0 % + 3 | |
DC volts | 4.000 V 40.00 V 400.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 0.5 % + 3 | |
AC millivolts | 400.0 mV | 0.1 mV | 3.0 % + 3 | |
DC millivolts | 400.0 mV | 0.1 mV | 1.0 % + 10 | |
Diode test2 | 2.000 V | 0.001 V | 10% | |
Resistance (Ohms) | 400.0 4.000 k 40.00 k 400.0 k 4.000 M 40.00 M | 0.1 0.001 k 0.01 k 0.1 k 0.001 M 0.01 M | 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 | |
Capacitance3 | 40.00 nF 400.0 nF 4.000 F 40.00 F 400.0 F 1000 F | 0.01 nF 0.1 nF 0.001 F 0.01 F 0.1 F 1 F | 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 | |
AC current A (40 Hz to 400 Hz) | 400.0 A 4000 A | 0.1 A 1 A | 1.5 % + 3 | |
AC current mA (40 Hz to 400 Hz) | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5 % + 3 | |
AC current A (40 Hz to 400 Hz) | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | |
DC current A | 400.0 A 4000 A | 0.1 A 1 A | 1.5 % + 3 | |
DC current mA | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5 % + 3 | |
DC current A | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | |
Backlight | Yes | |||
1All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. 2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA. 3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Model Number | FLUKE 17B, FLUKE 17B |
Brand | Fluke |
Warranty | 1 Year |
Digit Display | 4 Digit |
operating temperatures | 18 dgrC to 28 dgrC |
Function | Range | Resolution | Accuracy |
AC volts (40 Hz to 500Hz)1 | 4.000 V 40.00 V 400.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 1.0 % + 3 |
DC volts | 4.000 V 40.00 V 400.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 0.5 % + 3 |
AC millivolts | 400.0 mV | 0.1 mV | 3.0 % + 3 |
DC millivolts | 400.0 mV | 0.1 mV | 1.0 % + 10 |
Diode test2 | 2.000 V | 0.001 V | 10% |
Resistance (Ohms) | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ | 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 |
Capacitance3 | 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF | 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF | 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
Frequency1 Hz (10 Hz – 100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | 0.1 % + 3 |
Duty Cycle1 | 1 % to 99 % | 0.1 % | 1 % typical 4 |
AC current μA (40 Hz to 400 Hz) | 400.0 μA 4000 μA | 0.1 μA 1 μA | 1.5 % + 3 |
AC current mA (40 Hz to 400 Hz) | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5 % + 3 |
AC current A (40 Hz to 400 Hz) | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 |
DC current μA | 400.0 μA 4000 μA | 0.1 μA 1 μA | 1.5 % + 3 |
DC current mA | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5 % + 3 |
Additional Information:
Product Details:
Model Name/Number | Fluke 362 |
DC Current - Sensing Range | 200A |
AC Current - Sensing Range | 200A |
DC Voltage | 600 V |
Brand | Fluke |
AC Voltage | 600 V |
Resistance | 300/3000 |
AC current | 200A | 0.1A | 2% +- 5 digits (45-65Hz) 2.5% +- 5 digits (65-400Hz) |
DC current | 200A | 0.1A | 2% +- 5 digits |
AC voltage | 600 V | 0.1 V | 1.5% +- 5 digits (45-400Hz) |
DC voltage | 600 V | 0.1 V | 1% +- 5 digits |
Resistance | 300/3000 | 0.1/1 | 1% +- 5 digits |
Continuity | <=70 |
General Specifications | |||
Size (LxWxH) mm | 205 x 60 x 22 | ||
Clamp opening | 18 mm | ||
Weight | 196 g | ||
Safety rating | CAT III 600 V | ||
Warranty | 2 years |
Product Details:
Usage | Laboratory, Industrial |
Jaw size | 30 mm |
Range | 400.0 A |
Test leads | TL75 |
Battery | 2 AA batteries |
Data Hold Size | 208 x 58.5 x 28 |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | 2250-auto |
AC Current | 40A,400A,1000A |
DC Voltage | 4V,40V,400V,1000V Auto |
Brand | Meco |
AC Voltage | 4V,40V,400V,750V Auto 40-500Hz |
Frequency | 10.00 Hz,50.00 Hz,500.0 Hz,5.000 KHz,50.00KHz,500.0 KHz(Auto) |
Resistance | 400,4K,40K,400K,4M,40M Auto |
Sp Functions | Data Hold,Audible Continuity,Diode Test,% Duty Cycle |
Jaw Opening | 55mm Max |
AC Current40A, 400A, 1000AAC Voltage4V, 40V, 400V, 750V (Auto) (40-500Hz)DC Voltage4V, 40V, 400V, 1000V (Auto)Resistance400Ω, 4KΩ, 40KΩ, 400KΩ, 4MΩ, 40MΩ (Auto)Frequency10.00 Hz, 50.00 Hz, 500.0 Hz, 5.000 KHz, 50.00KHz, 500.0 KHz(Auto)Sp. FunctionsData Hold, Audible Continuity, Diode Test, % Duty CycleJaw Opening55mm Max.
Product Details:
Minimum Order Quantity | 1 Number |
Model Number | FLUKE117 |
Brand | Fluke |
Digit Display | 4 Digit |
Storage Temperature | -04 C -60 C |
Surge protection | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
Fuse for A input | 11 A, 1000 V FAST Fuse Fluke PN 803293 |
Bar graph | 33 segments, updates 32 per second |
Operating Temperature | -10 C -50 C |
Battery | 9 volt Alkaline, NEDA 1604A- IEC 6LR61 |
Display Type | Digital |
Specifications | |||
Maximum voltage between any terminal and earth ground |
| ||
Surge protection |
| ||
Fuse for A input |
| ||
Display |
| ||
Bar graph |
| ||
Operating Temperature |
| ||
Storage Temperature |
| ||
Battery type |
| ||
Battery Life |
|
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
AC Current | 40A, 400A |
Brand | Meco |
AC Voltage | 4V, 40V, 400V, 600V auto ranging |
Resistance | 200 , 2k , 20K , 200k , 2M , 20M auto ranging |
Color | Yellow |
Display Count | 4 digit |
Display | digital |
Models : | 36 AUTO, 400A AC, Auto Ranging |
AC Current | 40A, 400A |
AC Voltage | 4V, 40V, 400V, 600V (auto ranging) |
Resistance | 200 , 2k , 20K , 200k , 2M , 20M (auto ranging) |
Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | Industrial |
Models | 27 Auto - 400A AC, Auto Ranging |
AC Current | 2A, 20A, 200A, 400A (Auto Ranging) |
Jaw Opening | 25mm (max.) |
DC Voltage | 200mV, 2V, 20V, 200V, 600V |
Resistance | 200 , 2k , 20K , 200k , 2M , 20M (Auto Ranging) |
We are the leading supplier of Auto Ranging Digital Clamp Meter (27-Auto) made from high quality material at competitive prices.
Models | 27 Auto - 400A AC, Auto Ranging |
AC Current | 2A, 20A, 200A, 400A (Auto Ranging) |
AC Voltage | 2V, 20V, 200V, 600V (Auto Ranging) |
DC Voltage | 200mV, 2V, 20V, 200V, 600V |
Resistance | 200 , 2k , 20K , 200k , 2M , 20M (Auto Ranging) |
Sp. Functions | Data Hold, Audible Continuity, Diode Test, APO |
Jaw Opening | 25mm (max.) |
Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | Industrial |
Models | 72 AUTO, 400A AC, Auto Ranging |
AC Current | 40A, 400A (Auto Ranging) |
Temperature | -20C to 750C |
Resistance | 400 , 4k , 40K , 400k ,4M , 40M |
Jaw Opening | 25mm (max.) |
We are the leading supplier of Auto Ranging Digital Clamp Meter (72-auto) made from high quality material at competitive prices.
Models : | 72 AUTO, 400A AC, Auto Ranging |
AC Current | 40A, 400A (Auto Ranging) |
AC Voltage | 4V, 40V, 400V, 600V (Auto Ranging) |
DC Voltage | 400mV, 4V, 40V, 400V, 600V(Auto Ranging) |
Temperature | -20C to 750C |
Capacitance | 5nF, 50nF, 500nF, 5μF, 50μF, 200μF |
Frequency | 10Hz, 100Hz, 1000Hz,10KHz, 100KHz, 1000KHz,10MHz (Auto Ranging) |
Resistance | 400 , 4k , 40K , 400k ,4M , 40M |
Sp. Functions | Rel Test, NCV, Data Hold, Audible Continuity, Diode Test, APO |
Jaw Opening | 25mm (max.) |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Number | DILM817B |
Warranty | 1 Year |
Digit Display | 4 Digit |
DC Voltage | 0.1mv~1000V |
AC Current | 0.1MICRON A-10A |
DC Current | 0.1 MICRON A-10A |
DC Voltage Accuracy | (0.5%+3) |
Battery | 9V6F22 Battery |
Display Type | 4000 Counts |
Dimensions | 180mm x90mm x40mm |
DC Current Accuracy | (1.5+3) |
Frequency Accuracy | (0.1+3) |
Temperature Range | 55 C - 1000 C |
Temperature Accuracy | (2.0+2 C) |
Item weight | Approx 300g |
Feature
-4000 counts
-Diode test/Buzzer
-Temperature Test
-Frequency/Duty Cycle
-Relative Measurement
-Data Hold
-Auto Power Off
-Auto/Manual Ranging
-Holster (secondary injection)
-Mechanical/Electronic Protection System
-In conformity with IEC 1010 CAT II 1000V
-Convenient Fuse/Battery Change Design
-Battery Life up to 500 Hours
Specification
Specifications | Range | Accuracy DIL817B | |
DCVoltage | 0.1mv~1000V | +-(0.5% 3) | |
ACVoltage | 0.1mv~1000V | +-(1.0% 3)40Hz~500Hz | |
DCCurrent | 0.1A~10A | +-(1.5% 3) | |
ACCurrent | 0.1A~10A | +-(1.5% 3)40Hz~200Hz | |
Resistance | 0.1~40M | +-(0.5% 2) | |
Capacitance | 0.01nF~100F | +-(3.0% 5) | |
Frequency/DutyCycle | 10Hz~100KHz | +-(0.1% 3) | |
Temperature | -55 DegreeC~1000 DegreeC | +-(2.0% 2 DegreeC) | |
Feature | |||
Display | 4000Counts | ||
Datahold |
| ||
Temperaturetest |
| ||
Frequency/DutyCycle |
| ||
Diodetest/Buzzer |
| ||
Relativemeasurement |
| ||
Continuity |
| ||
Autopoweroff |
| ||
Auto/manualranging |
| ||
Electronicprotectionsystem |
| ||
EK1Dictate |
| ||
General | |||
Powersupply | 9V6F22Battery | ||
Weight | Approx300g | ||
Size | 180mmx90mmx40mm | ||
SafetyRating | CEETACAT.II1000VRoHS | ||
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Make | Precise |
Brand | Precise |
Measure Range | 50~1000 ACV. |
Operating voltage | DC 3V 2 x AAA |
batteries | CAT IV 1000V. |
Color | Blue |
AC non-contact voltage testers
AC non-contact voltage testers from Nicety are easy to use - just touch the tip to a terminal strip, outlet, or supply cord. When the tip glows red, you know there's voltage present.
700B Non Contact Volage tester
Measure Range 50~1000 ACV.
Audible and visual indication.
Convenient size with pocket clip.
Flashlight
Operating voltage DC 3V 2 x AAAbatteries.
CAT IV 1000V.
instrument is Used to Check produces with Voltage
It comes with Buuzzer and Light