A multimeter (also called a volt-ohm-milliammeter, VOM) is a versatile measuring instrument used in electronics and electrical engineering to measure multiple electrical quantities in a single device.
š Main Functions of a MultimeterVoltage Measurement (V)
DC Voltage (Vā) – used for batteries, circuits, electronics.
AC Voltage (V~) – used for mains electric
...Read More




ā¹ 5920 / NumberGet Latest Price
| Minimum Order Quantity | 1 Number |
| Type | Industrial Digital |
| Brand | Fluke |
| Digit Display | 4 Digit |
| Warranty | 1 Year |
| Model Number | FLUKE117 |
| Model Name/Number | 117 |
| Operating Temperature | -10 C -50 C |
| Battery | 9 volt Alkaline, NEDA 1604A- IEC 6LR61 |
| Display Type | Digital |
| Surge protection | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
| Specifications | |||
| Maximum voltage between any terminal and earth ground |
| ||
| Surge protection |
| ||
| Fuse for A input |
| ||
| Display |
| ||
| Bar graph |
| ||
| Operating Temperature |
| ||
| Storage Temperature |
| ||
| Battery type |
| ||
| Battery Life |
| ||



ā¹ 3360 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Type | Industrial Digital |
| Model Name/Number | Fluke 101 |
| BRAND | FLUKE |
| colour | Yellow |
| V AC Range | 600.0mV |
| V AC Resolution | 0.1mV |
| V AC Accuracy | 3.0 3digit |
| V DC Range | 6.000V |
| V DC Resolution | 0.001V |
| V DC Accuracy | 0.5 3 digit |
|
| V AC (40-500Hz) | Range | 600.0 mV 6.000 V 60.00 V 600.0 V |
| Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V | |
| Accuracy | 3.0%±3 digit 1.0%±3 digit | |
| V DC | Range | 6.000 V 60.00 V 600.0 V |
| Resolution | 0.001 V 0.01 V 0.1 V | |
| Accuracy | 0.5%±3 digit | |
| Resistance Ohms | Range | 400.0 4.000 k 40.00 k 400.0 k 4.000 M 40.00 M |
| Resolution | 0.1 0.001 k 0.01 k 0.1 k 0.001 M 0.01 M | |
| Accuracy | 0.5 %±3 digit 0.5 %±2 digit 0.5 %±2 digit 0.5 %±2 digit 0.5 %±2 digit 1.5%±3 digit | |
| Capacitance | Range | 50.00 nF 500.0 nF 5.000 μF 50.00 μF 100.0 μF |
| Resolution | 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF | |
| Frequency (10 Hz – 100 kHz) | Range | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
| Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | |
| Duty Cycle | Range | 0.1 % to 99.9 % |
| Resolution | 0.1 % | |



ā¹ 7900 / PieceGet Latest Price
| Current Rating | 5A |
| Digit Display | 4 Digit |
| Brand | Fluke |
| Model Number | 15B FLUKE |
| DC Voltage | 4.000 V |
| AC Current | 400.0 A |
| DC Current | 400.0 A |
| Display Type | Digtal |
| DC Voltage Accuracy | 0.5 |
| AC Voltage | 4.000 V |
| Function | Range | Resolution | Accuracy | |
| AC volts (40 Hz to 500Hz)1 | 4.000 V 40.00 V 400.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 1.0 % + 3 | |
| DC volts | 4.000 V 40.00 V 400.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 0.5 % + 3 | |
| AC millivolts | 400.0 mV | 0.1 mV | 3.0 % + 3 | |
| DC millivolts | 400.0 mV | 0.1 mV | 1.0 % + 10 | |
| Diode test2 | 2.000 V | 0.001 V | 10% | |
| Resistance (Ohms) | 400.0 4.000 k 40.00 k 400.0 k 4.000 M 40.00 M | 0.1 0.001 k 0.01 k 0.1 k 0.001 M 0.01 M | 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 | |
| Capacitance3 | 40.00 nF 400.0 nF 4.000 F 40.00 F 400.0 F 1000 F | 0.01 nF 0.1 nF 0.001 F 0.01 F 0.1 F 1 F | 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 | |
| AC current A (40 Hz to 400 Hz) | 400.0 A 4000 A | 0.1 A 1 A | 1.5 % + 3 | |
| AC current mA (40 Hz to 400 Hz) | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5 % + 3 | |
| AC current A (40 Hz to 400 Hz) | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | |
| DC current A | 400.0 A 4000 A | 0.1 A 1 A | 1.5 % + 3 | |
| DC current mA | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5 % + 3 | |
| DC current A | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | |
| Backlight | Yes | |||
| 1All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. 2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA. 3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). | ||||



ā¹ 9650 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Model Number | FLUKE 17B, FLUKE 17B |
| Brand | Fluke |
| Warranty | 1 Year |
| Digit Display | 4 Digit |
| operating temperatures | 18 dgrC to 28 dgrC |
| Function | Range | Resolution | Accuracy |
| AC volts (40 Hz to 500Hz)1 | 4.000 V 40.00 V 400.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 1.0 % + 3 |
| DC volts | 4.000 V 40.00 V 400.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 0.5 % + 3 |
| AC millivolts | 400.0 mV | 0.1 mV | 3.0 % + 3 |
| DC millivolts | 400.0 mV | 0.1 mV | 1.0 % + 10 |
| Diode test2 | 2.000 V | 0.001 V | 10% |
| Resistance (Ohms) | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ | 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 |
| Capacitance3 | 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF | 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF | 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
| Frequency1 Hz (10 Hz – 100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | 0.1 % + 3 |
| Duty Cycle1 | 1 % to 99 % | 0.1 % | 1 % typical 4 |
| AC current μA (40 Hz to 400 Hz) | 400.0 μA 4000 μA | 0.1 μA 1 μA | 1.5 % + 3 |
| AC current mA (40 Hz to 400 Hz) | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5 % + 3 |
| AC current A (40 Hz to 400 Hz) | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 |
| DC current μA | 400.0 μA 4000 μA | 0.1 μA 1 μA | 1.5 % + 3 |
| DC current mA | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5 % + 3 |


ā¹ 23000 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Current Rating | 300A |
| Digit Display | 4 Digit |
| DC Voltage | 200m-2V 0.5,20-200-600V 0.8 |
| Battery | 6F22 9V X 1 |
| Item weight | 170g |
| Display Type | Digital |
| Size | 138 X 69 X 31mm |
| AC Voltage | 200-600V 1.5 |
| Power | 6F22 9V X 1 |
We are betrothed to provide a high quality collection of Digital Multimeter. The offered digital multimeter is used in various electrical and electronic applications for reading of voltage and current level. This digital multimeter is manufactured at our hi-tech production unit using the best quality components and advanced technology under the strict guidance of our highly skilled professionals. Moreover, this digital multimeter can be availed by our clients at the most reasonable rates.
Techincal Specification :
Display: 1999
Voltage DC: 200m/2V ± 0.5%,20/200/600V ± 0.8%
Voltage AC: 200/600V ± 1.5%
Current DCt: 200μ/2m/20mA ± 1.0%, 200mA± 2.0%, 10A ± 3.0%
Resistance: 200/2K/20K/200K/2MΩ ± 1.0%
hFE: 1 ~ 1000
Diode test Data hold
Back light
Continuity checking with Buzzer
Power: 6F22(9V) × 1Dimension: 138 × 69 × 31mm
Weight:170g (batteries included)

ā¹ 1550 / NumberGet Latest Price
| Minimum Order Quantity | 1 Number |
| Model Name/Number | DILM815B |
| DC Voltage Accuracy | 0.5- 3 |
| DC Voltage Range | 0.1mv -1000V |
| A C Voltage Range | 0.1mv- 1000V |
| DC Current Range | 0.1A - 10A |
| A C Current Range | 0.1A - 10A |
Feature
-4000 counts
-Diode test/Buzzer
-Temperature Test
-Frequency/Duty Cycle
-Relative Measurement
-Data Hold
-Auto Power Off
-Auto/Manual Ranging
-Holster (secondary injection)
-Mechanical/Electronic Protection System
-In conformity with IEC 1010 CAT II 1000V
-Convenient Fuse/Battery Change Design
-Battery Life up to 500 Hours
Specifications | Range | Accuracy DIL815B | |
DCVoltage | 0.1mv~1000V | +-(0.5% 3) | |
ACVoltage | 0.1mv~1000V | +-(1.0% 3)40Hz~500Hz | |
DCCurrent | 0.1A~10A | +-(1.5% 3) | |
ACCurrent | 0.1A~10A | +-(1.5% 3)40Hz~200Hz | |
Resistance | 0.1~40M | +-(0.5% 2) | |
Capacitance | 0.01nF~100F | +-(3.0% 5) | |
Feature | |||
Display | 4000Counts | ||
Datahold |
| ||
Diodetest/Buzzer |
| ||
Relativemeasurement |
| ||
Continuity |
| ||
Autopoweroff |
| ||
Auto/manualranging |
| ||
Mechanical/Electronicprotectionsystem |
| ||
EK1Dictate |
| ||
General | |||
Powersupply | 9V6F22Battery | ||
Weight | Approx300g | ||
Size | 180mmx90mmx40mm | ||
SafetyRating | CEETACAT.II1000VRoHS | ||




ā¹ 4600 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Digit Display | 4 Digit |
| DC Voltage | 600 V |
| Model Number | Fluke 106 |
| Features | Safety rating by CAT III 600 VAC/DC current, AC/DC voltage |
| DC Current | 4.000 A |
| Accuracy | +- 0.5% + 3 |
| Resistance Range | 40 M ohm |
| DC Current Accuracy | 10A Max |
| Frequency | 50Hz - 100 kHz |
| DC Voltage Accuracy | 0.5 |
| ccuracy Specifications | ||||
| Function | Range | Resolution | Accuracy | |
| AC Volts1 | 6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
1.0 % + 3 | |
| DC Volts | 6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
0.5 % + 3 | |
| AC Millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 | |
| Diode Test2 | 2.000 V | 0.001 V | 10 % | |
| Resistance (Ohms) |
400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 |
|
| Capacitance3 | 50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
|
| Frequency4 Hz (10 Hz – 100 kHz) |
50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
NA | |
| Duty Cycle4 | 1 % to 99 % | 0.1 % | NA | |
| AC Current (40 Hz to 200 Hz) |
4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | |
| DC Current | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | |

ā¹ 1525 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Model Number | DILM817B |
| Warranty | 1 Year |
| Digit Display | 4 Digit |
| DC Voltage | 0.1mv~1000V |
| AC Current | 0.1MICRON A-10A |
| DC Current | 0.1 MICRON A-10A |
| DC Voltage Accuracy | (0.5%+3) |
| Battery | 9V6F22 Battery |
| Dimensions | 180mm x90mm x40mm |
| Display Type | 4000 Counts |
Feature
-4000 counts
-Diode test/Buzzer
-Temperature Test
-Frequency/Duty Cycle
-Relative Measurement
-Data Hold
-Auto Power Off
-Auto/Manual Ranging
-Holster (secondary injection)
-Mechanical/Electronic Protection System
-In conformity with IEC 1010 CAT II 1000V
-Convenient Fuse/Battery Change Design
-Battery Life up to 500 Hours
Specification
Specifications | Range | Accuracy DIL817B | |
DCVoltage | 0.1mv~1000V | +-(0.5% 3) | |
ACVoltage | 0.1mv~1000V | +-(1.0% 3)40Hz~500Hz | |
DCCurrent | 0.1A~10A | +-(1.5% 3) | |
ACCurrent | 0.1A~10A | +-(1.5% 3)40Hz~200Hz | |
Resistance | 0.1~40M | +-(0.5% 2) | |
Capacitance | 0.01nF~100F | +-(3.0% 5) | |
Frequency/DutyCycle | 10Hz~100KHz | +-(0.1% 3) | |
Temperature | -55 DegreeC~1000 DegreeC | +-(2.0% 2 DegreeC) | |
Feature | |||
Display | 4000Counts | ||
Datahold |
| ||
Temperaturetest |
| ||
Frequency/DutyCycle |
| ||
Diodetest/Buzzer |
| ||
Relativemeasurement |
| ||
Continuity |
| ||
Autopoweroff |
| ||
Auto/manualranging |
| ||
Electronicprotectionsystem |
| ||
EK1Dictate |
| ||
General | |||
Powersupply | 9V6F22Battery | ||
Weight | Approx300g | ||
Size | 180mmx90mmx40mm | ||
SafetyRating | CEETACAT.II1000VRoHS | ||
Vikram Pahwa (Manager)
Sudershan Measuring And Engineering Pvt. Ltd.
Ground Floor, 4781, Hauz Qazi, Near Chawri Bazar Metro Statin, Hauz Qazi, New Delhi - 110006, Delhi, India