Surface roughness, for purposes of this forum, is the result of some machining process and its effect on the material surface in question.
Skid type surface roughness testers are common instruments used on the shop floor. A diamond stylus is traversed across the specimen and a piezoelectric pickup records all vertical movement. Peaks and valleys are recorded and converted into a known value of a given parameter.
Parameters differ in how they approach looking at peaks and valleys. The most popular parameter is “Ra”. Ra is commonly defined as the arithmetic average roughness. While the Ra parameter is easy and efficient, there are other parameters that can be more specific and useful depending on the application requirements. It is the parameters that enable us to define surface roughness.
Today, for the purpose of checking Ra values, the use of portable, hand held, surface roughness testers are not only economical, but are digital and easy to use. These surface roughness testers are a given necessity for any shop floor that receives work with Ra requirements.
Surface Roughness Tester TR110 Plus
Features
· Pocket-size & economical price
· Large measuring range suitable for most materials
· Measures flat, outer cylinder and sloping surface
· Both Ra and Rz parameters in one instrument
· Features external calibration at keyboard
· Standard conform to ISO and DIN
· Rechargeable batteries, work while charging
· TR110 is equipped with Li-ion battery and backlight.
Additional Information:
Backed by our in-depth industry expertise, we offer a wide range of Surface Roughness Tester at competitive prices. Our range is provided in various specifications that can be personalized as per the requirement of our clients. We also check our range on the various parameters to assure its efficiency.
Features :
Technical Specification :
TR110 | |
Roughness parameter | Ra, Rz |
Tracing length | 6mm |
Tracing speed | 1.0mm/sec |
Cut-off lengths | 0.25mm/0.8mm/2.5mm |
Evaluation length | 1.25mm/4.0mm/5.0mm |
Measuring range | Ra: 0.05-10.0µm Rz: 0.1-50µm |
Tolerance | ±15% |
Repeatability | <12% |
Filter | RC analogue |
Pick-up | Piezoelectric |
Radius and angle of the stylus point | Diamond, Radius : 10± 2.5µm Angle: 90 (+5 or -10 ) |
Operating temperature | 0-40oC |
Humidity | <80% |
Storing temperature | -25 ~60oC |
Ventilation | Grade 3 |
Power supply | 3.6V/2XNiMh-batteries |
Back light | No |
Charger | DC 9V, 8 - 12 hours (recharging time) |
Dimensions (LXWX H) | 125X73X26mm |
Weight | 200g |
Additional Information:
Technical Specifications :
TR200 | |
Roughness parameters | Ra, Rz, Ry, Rq, Rt, Rp, Rmax, Rv, R3z, RS, RSm, RSk, Rmr, |
Assessed profiles | Primary profile (P) |
Measuring system | Metric, English |
Display resolution | 0.01µm |
Data output | RS232 |
Measuring Range | ±20µm, ±40µm, ±80µm |
Cutoff length (L) | 0.25mm / 0.8mm / 2.5mm/Auto |
Evaluation length | 1~5L (selectable) |
Tracing length | (1~5)L + 2L (selectable) |
Digital filter | RC, PC-RC, Gauss, D-P |
Max. tracing length | 17.5mm/0.71inch |
Min. tracing length | 1.3mm/0.051inch |
Pick-up | Standard pickup TS100, inductive, Diamond stylus radius 5µm , angle of stylus 90oC |
Tolerance | ±10% |
Repeatability | <6% |
Power | Li-ion battery rechargeable |
Dimensions | 141mm X56mm X48mm |
Weight | 480g |
Additional Information: